Invasive kV, Time, and mA |
|
| DIAGNOSTIC X-RAY PRODUCTS |
|
Wide Beam CT Ion Chambers
Reference Class Ion Chambers
|
|
| |
|
|
|
|
|
| |
| |
For the calibration and analysis of X-ray generator systems |
|
| |
| |

|
|
USED WORLDWIDE FOR - |
|
MEASURE - |
| |
• |
X-ray machine manufacturing |
|
|
• |
kVp (anode, cathode, and anode + cathode) |
| |
• |
Troubleshooting |
|
|
• |
mA and mAs Anode current |
| |
• |
Annual Calibration |
|
|
• |
Filament current |
| |
• |
Installation |
|
|
• |
Exposure time |
| |
• |
Acceptance Testing |
|
|
|
|
|
| |
DYNALYZER IIIU HIGH VOLTAGE UNIT - The Dynalyzer IIIU is one of the most accurate tools for the calibration and analysis of x-ray generator systems.
Connected between the generator and the x-ray tube unit, it isolates the signals and provides an output proportional to kV, mA and filament current. These ground-referenced analog signals may be routed to external test equipment, such as the Dynalyzer III digital Display or an oscilloscope. Unlike non-invasive instruments, the Dynalyzer provides the user with direct kV measurements unaffected by tube target material or filtration. |
|
|
|
| |
Measure kVp |
|
Quickly and accurately measure without a scope |
| Measure Fluoro |
Generator parameters measured in real-time with "Auto Trigger" mode |
| kV Delay |
Use of kV Delay allows user to ignore overshoot |
| Exposure Recall |
Allows user to display up to 10 previous exposures |
| Coefficient of Variation |
Accessible with just the touch of a button |
| |
|
|
| |
HIGH VOLTAGE TERMINALS |
|
| |
|
Federal Standard X-ray cable
receptacles
(3-conductor) conform
to
US Federal
Standards 72
|
|
|
|
 |
|
| |
| |
kV Accuracy |
± 1% |
|
10 kV to 150 kV |
|
| Anode Current |
± 2% |
1 mA to 2 Amps(8ms pulse maximum) Selectable sensitivity for more accuracy at low mA |
| |
|
| Filament Current |
± 1% db (12%) |
DC to 20 kHz |
| All specifications subject to change. |
|
|
|
|
|
|
|
|
|
|
|
|
| |
DYNALYZER III DIGITAL DISPLAY / PRINTER -As an element of the Dynalyzer system, the Digital Display provides a wide range of x-ray measurement features for rapid calibration, compliance testing, and trouble- shooting. It may be used with the Dynalyzer II, III, IIIA-CT IIIU High Voltage Unit, conventional oscilloscope
and voltmeter for complete analysis.
|

| |
| |
kV Accuracy |
± (0.75 kV + 0.5%) |
|
10 kV to 150 kV |
|
| Anode Current |
± 2% |
1 mA to 2 Amps |
| Filament Current |
± (0.05A + 0.7%) |
|
| Exposure Time |
± (0.25 ms + 0.5%) |
|
| All specifications subject to change. |
|
|
|
|
|
|
|
|
|
|
|
|
Refer to Radcal price list for other options and accessories |
|
| • |
Dynalyzer IIIU High Voltage Unit comes standard for 3 conductor applications. Includes two 12 foot
|
| |
coaxial cables and dummy plugs. (4 conductor applications Dynalyzer available on special request) |
| • |
Heavy duty shipping container (M-96321) for Dynalyzer III Digital Display (M-96320P) (order separately) |
| • |
Heavy duty shipping container (M-96115) for Dynalyzer IIIU (M-96311) (order separately) |
| • |
High voltage cables (two 5-foot cables recommended) |
|
|
|
|
|
|
|
|
|
|