* Laptop Computer not included.
Optional XLPRO Software sold separately.


Basic and Advanced kVp Functions with mAs



For Radiography, Fluoroscopy, Mammography, CT, and Dental


            OVERVIEW OF FEATURES AND BENEFITS

Increased Productivity
Intuitive, quick setup, small footprint, convenient portability.
Flash HVL (diagnostic range), beam hardness, invasive/non-invasive mAs.

Accuracy and Confidence
Auto-ranging, hardness corrected FFT kV. Accurate kVp for AMX4+ and AMX 700 portables.

Value
Basic and advanced function choices add utility at no extra cost.
Easy upgrades: we invented expand-as-you-grow-sensors and firmware for x-ray diagnostics.
Radcal designed for durability; 35+ years of know-how.

Please see below for ACCU-kV® Analyzer plug-and-play sensor user options




FFT kV SENSORS with FLASH HVL (diagnostic range)

The FFT kV Sensors with Flash HVL (diagnostic range) feature:
Calibration Accuracy: Diagnostic, ± 1 kV or ± 1 % whichever is largest; Mammo ± 0.5 kV

40X12-W Accu-kV
The sensor for Diagnostic range (40 kV to 160 kV) measurements
Besides kVp, also measures, displays, and compensates for beam hardness (add ± 1 % when on). Inherently correctly reads AMX4+ and AMX 700 portables. Flash HVL: ± 0.3 mm Al and ± 10 % of reading, 1-23 mm total equivalent thickness Al, 40-160 kVp.
40X9-Mo Accu-kV
The sensor for Mammographic range measurements
This sensor is specifically designed for Mo-Mo mammographic beams.

Recommended for starter kit configuration. 
 



mA, mAs SENSORS

The mA and mAs Sensors come in both invasive and non-invasive models:

90M9 Invasive Sensor -- (requires kV sensor to be in beam)
Resolution: Greater of 3-4 digits or ± 0.015 mA, 0.001
mAs
mA accuracy at dc: ± 0.2% of reading plus resolution
mAs accuracy (1-s pulse): ± 5 µAs or 0.2 % of reading, whichever is greater.

Click PDF Specifications

90M10 Non-Invasive Sensor -- (requires kV sensor to be in beam)
Resolution: Greater of 3-4 digits or ± 0.015 mA, 0.001
mAs
RMS integrated noise for 1-s pulse: 0.53 mA or 0.53 mAs
mA accuracy at dc: ± 4% of reading, limited by noise below 15 mA
mAs accuracy (1-s pulse): ± 4% of reading, limited by noise below 15 mAs

Click PDF Specifications

 

90M9 INVASIVE SENSOR
Optional 90M9 Invasive sensor works in conjunction with the ACCU-kV® Analyzer.

 

MEASUREMENT FUNCTIONS

The Measurement Functions feature:
Built-in digital display or computer display with optional XLPRO software

Dose Rate kV Time mA Beam Quality
Dose Rate (Relative) kV peak, kV average,
kV practical for: pulse (single exposure),
fluoro, and dental
Seconds
Minutes
Hours
mA
mAs
Filtration (Al and Cu equivalents)
HVL
         
         

OTHER FEATURES

Other Features include:
Single exposure multiple data displays, XLPRO Software, and Portability


SINGLE EXPOSURE MULTIPLE DATA DISPLAYS
The ACCU-PRO™ Analyzer captures multiple data in one exposure and shows these in two scrollable display screens.

DATA DISPLAY EXAMPLES


XLPRO SOFTWARE
XLPRO software for auto data capture, waveforms, modifiable templates and remote control.

XLPRO SOFTWARE EXAMPLES

 

PORTABLE CARRYING CASE
ACCU-PRO™ Analyzer cases afford convenient and easy portability especially for the air traveler.


PORTABILITY



CARRYING CASE CONTENTS
The ACCU-kV® Analyzer case contents are easily accessible and protected for durability.