Basic and Advanced kVp Functions with mAs
For Radiography, Fluoroscopy, Mammography, CT, and Dental
OVERVIEW
OF FEATURES AND BENEFITS
| Increased
Productivity |
| •
Intuitive, quick setup, small footprint,
convenient portability. |
| •
Flash HVL (diagnostic range), beam hardness,
invasive/non-invasive mAs. |
|
Accuracy and Confidence |
| •
Auto-ranging, hardness corrected FFT kV. Accurate kVp for
AMX4+ and AMX 700 portables. |
| Value |
| •
Basic and advanced function choices add utility at no extra
cost. |
|
• Easy
upgrades: we invented expand-as-you-grow-sensors and firmware
for x-ray diagnostics. |
| •
Radcal designed for durability; 35+
years of know-how. |
Please
see below for ACCU-kV® Analyzer plug-and-play sensor user
options

FFT kV SENSORS with FLASH HVL (diagnostic range)
The FFT kV Sensors with Flash HVL
(diagnostic range) feature:
Calibration Accuracy: Diagnostic, ±
1 kV or ± 1 % whichever is largest; Mammo ± 0.5 kV
40X12-W
Accu-kV
The
sensor for Diagnostic range (40 kV to 160 kV) measurements
Besides kVp, also measures, displays, and compensates for beam hardness (add ± 1
% when on). Inherently correctly reads AMX4+ and AMX 700 portables. Flash HVL: ± 0.3 mm Al and ± 10 % of reading,
1-23 mm total equivalent thickness Al, 40-160 kVp. |
|
40X9-Mo
Accu-kV
The sensor for Mammographic range measurements
This sensor is specifically designed for Mo-Mo mammographic
beams.
Recommended
for starter kit configuration.
|
|
| |
mA, mAs SENSORS
The mA and mAs Sensors come
in both invasive and non-invasive models:
|
90M9
Invasive Sensor -- (requires kV sensor to be in beam)
Resolution: Greater of 3-4 digits or ± 0.015
mA, 0.001
mAs
mA accuracy at dc: ± 0.2% of reading plus resolution
mAs accuracy (1-s pulse): ± 5 µAs or 0.2 % of reading,
whichever is greater.
Click PDF Specifications
|
|
90M10
Non-Invasive Sensor -- (requires kV sensor to be in beam)
Resolution: Greater of 3-4 digits or ± 0.015
mA, 0.001
mAs
RMS integrated noise for 1-s pulse: 0.53 mA or 0.53 mAs
mA accuracy at dc: ± 4% of reading, limited by noise
below 15 mA
mAs accuracy (1-s pulse): ± 4% of reading, limited by
noise below 15 mAs
Click PDF Specifications |
|
90M9
INVASIVE SENSOR
Optional 90M9 Invasive sensor works in conjunction with
the ACCU-kV® Analyzer.

MEASUREMENT
FUNCTIONS
The
Measurement Functions feature:
Built-in digital display or computer display with optional
XLPRO software
|
| Dose
Rate |
kV |
Time |
mA |
Beam
Quality |
| Dose
Rate (Relative) |
kV peak, kV average,
kV practical for: pulse (single exposure),
fluoro, and dental
|
Seconds
Minutes
Hours
|
mA
mAs
|
Filtration
(Al and Cu equivalents) HVL
|
| |
|
|
|
|
| |
|
|
|
|
|
|
|
|
OTHER
FEATURES
Other
Features include:
Single exposure multiple data displays,
XLPRO Software, and Portability
|
SINGLE
EXPOSURE MULTIPLE DATA DISPLAYS
The ACCU-PRO™ Analyzer captures multiple data in one exposure
and shows these in two scrollable display screens.

XLPRO
SOFTWARE
XLPRO software for auto data capture, waveforms, modifiable
templates and remote control.
XLPRO
SOFTWARE EXAMPLES

| PORTABLE
CARRYING CASE
ACCU-PRO™ Analyzer cases afford convenient and
easy portability especially for the air traveler.
PORTABILITY
CARRYING
CASE CONTENTS
The ACCU-kV® Analyzer case contents are easily accessible