| DIAGNOSTIC X-RAY PRODUCTS |
Wide Beam CT Ion Chambers
Reference Class Ion Chambers
|
| |
|
|
|
|
| |
| |
Radiography, Fluoroscopy, Mammography and CT |
|
| |
|
Mammography
Mammographic Accreditation Phantom
The required standard for
image quality evaluations |
| |
 |
| Model 015 |
| |
|
|
| |
Meet
MQSA requirements.
The Mammographic Accreditation Phantom was designed
to test the performance of a mammographic system by a quantitative evaluation
of the system’s ability to image small structures similar to those
found clinically. Objects within the phantom simulate calcifications,
fibrous calcifications in ducts, and tumor masses.
The Phantom is designed to determine if your mammographic system can
detect small structures that are important in the early detection of
breast cancer. Test objects within the phantom range in size from those
that should be visible on any system to objects that will be difficult
to see even on the best mammographic systems. The 4.4 cm thick Mammograhpic
Phantom is made of a 7 mm wax block insert containing 16 sets of test
objects, a 3.4 cm (approx. 1-3/8") thick acrylic base, and a 3
mm (1/8") thick cover. All of this together approximates a 4.5
cm compressed breast of average glandular /adipose composition. Included
in the wax insert are aluminum oxide (Al 2 O 3 ) specks to simulate
microcalcifications. Six different size nylon fibers simulate fibrous
structures and five different size lens shaped masses simulate tumors.
Each Phantom includes a 4mm acrylic step wedge, operating instructions,
faxitron x-ray image and magnifying lens. |
|
| |
 |
|
| |

|
Tissue-Equivalent
Phantom for Mammography
A Refined Quality Assurance
Tool for Today's Advanced Imaging Systems |
| |
 |
| Model 011A |
| |
| |
Proven
simulation technology enables the use of tissue-equivalent, realistically-shaped
phantoms for mammographic quality assurance.
CIRS resin material mimics the photon attenuation coefficients of a
range of breast tissues. Average elemental composition of the human
breast being mimicked is based on the individual elemental composition
of adipose and glandular tissue reported by Hammerstein.
Attenuation coefficients
are calculated by using the "mixture rule" and the Photon
Mass Attenuation and Energy Absorption Coefficient Table of J.H. Hubbell.
The CIRS Model 11A Breast Phantom contains targets that are engineered
to test the threshold of the new generation of mammography machines.
Model 11A is 4.5 cm thick and simulates a 50% glandular tissue composition.
The Model 11A was designed to test the performance of any mammographic
system. Objects within the phantom simulate calcifications, fibrous
calcifications in ducts and tumor masses. Test objects within the phantom
range in size from those that should be visible on any system to objects
that will be difficult to resolve on the best mammographic systems.
CIRS mammography phantoms are also manufactured in 4cm, 5cm and 6cm
thicknesses with various glandular eequivalences.
The methodology and design of these phantoms was developed by Dr. Panos
Fatouros and his associates at the Medical College of Virginia. |
|
| |
 |
|
| |
 |
Digital Mammography Phantoms
Tissue equivalent test tools |
| |
|
|
|
Model
081:
Digital
Step Wedge
|
Model
082:
Full
Field Low Contrast Phantom
|
Model
083:
Small Low Contrast Phantom
-
Standard contrast objectis 10% grandularity above ground (other
contrasts available) Digital count
DIA. 4.5, 4.0, 3.5, 3.0, 2.5, 2.0, 1.5mm, THK.
.25, .40, .80, 1.2, 2.0, 3.0, 4.5mm
|
|
|
 |
|
 |
Stereotactic
Needle Biopsy Training Phantom
A non-leak, tissue
equivalent, compressible biopsy training phantom |
| |
 |
| Model 013 |
| |
This
phantom closely mimics properties of the human breast. It is an ideal
teaching tool and practice medium for mammographic needle biopsy procedures.
Model 13 also serves as an excellent quality assurance testing device
for stereotactic systems and should be used whenever a new system
is installed or repaired to insure accurate needle placement.
Each
solid mass can be biopsied multiple times. The phantom is constructed
from a solid material so it will not leak when punctured.
Model 13 is an excellent research and development or demonstration tool
for manufacturers of mammography equipment.
Phantom Features:
- Compressible.
- Proprietary
gel simulates the physical density and mass attenuation of "BR
12."
- A physical
consistency similar to human tissue combined with an elastic, skin-like
membrane enables palpation of embedded structures and accurately
simulates needle resistance.
- Anthropomorphic
shape for accurate simulation of breast compression.
- Gel will not
dry out after initial needle punctures thus extending storage life.
- Contains dense
masses and calcifications.
|
|
 |
 |
ACR Radiography Fluoroscopy Accreditation
Phantom
|
 |
| Model 903 |
| |
| |
The
CIRS Model 903 ACR Radiography / Fluoroscopy Phantom is designed
to be an integral part of the American College of Radiology (ACR) Radiography
/ Fluoroscopy Accreditation Program. This voluntary program provides
physicians with an opportunity for a comprehensive peer review of their
Radiography / Fluoroscopy facil-ity, personnel qualifications, image
quality and quality assurance programs.
The ACR Radiography / Fluoroscopy Accreditation Phantom can be used
for initial QA assessment and routine monthly QA testing to help ensure
patients are receiving the best possible x-ray examinations.
The CIRS Model 903 is manufactured from PMMA equivalent epoxy that offers
the same x-ray attenuation properties as acrylic with sig-nificantly
greater durability.
The overall phantom mea-sures 25 cm wide x 25 cm long x 20.7 cm high
and consists of three attenuation -plates, one test object plate and
a detachable stand for easy, reproducible set-up. Test objects include
high-resolution copper mesh targets from 12 – 80 lines per inch,
two separate contrast-detail test objects. |
|
 |
 |
Nema SCA&I Cardiovascular Fluoroscopic Benchmark
Phantom |
 |
| Model 901 |
| |
| |
The
CIRS Model 901NEMA - SCA;I phantom was designed
to evaluate and standardize catheterization image quality. It
is the result of collaborative efforts between the Society for
Cardiac Angiography and Interventions and the National Electric
Manufacturers Association. The phantom specifically enables
voluntary compliance with the recently published performance
standard NEMA XR 21. |
|
| |
| |
The
Model 901 is manufactured from PMMA with x-ray absorption
properties similar to soft tissue at diagnostic energies. It
contains a variety of static and dynamic test targets for objective
assessment of resolution, motion unsharpness and radiation exposure.
The sectional design allows for configuration in a wide range
of thicknesses from 5cm to 30 cm simulating PA thicknesses from
infants to large adult patients. |
|
| |
|
|
| |
The
phantom is ideal for routine assessment of the entire imaging
system. |
|
| |
 |
|
 |
Mammoview
Markers 021 & 022
Simple to use and compatible with any mammography x-ray system |
 |
| Model 022 |
| |
| |
These
radio-opaque mark-ers are designed to provide a clear indication
of position, which can be read directly from x-ray film. They are
manufactured in accordance with abbreviations recom-mended by the
ACR. |
|
| |
| Each marker is manufactured to be clearly visible on x-ray film
only in the mammo-graphic energy range. |
| |
| Each set of markers comes with an acrylic holding device designed
to be mounted near the x-ray unit for easy access. |
| |
| The CIRS Mammoview Mark-ers are quick and easy to use. Simply mount
the acrylic holder near the mammogra-phy unit in close proximity
to the buckey. Firm pres-sure applied to the suction cup will hold
the marker in place on any smooth surface. Mammoview Markers are
usable on any mammography system. |
| |
| Benefits: |
- Fast and
simple to use.
- Meets
all requirements for standardized terminology set forth by the
American College of Radiology.
- For all
mammography systems.
- Custom,
personalized ID markers also available.
|
 |
 |
CT
CT Dose Phantom
Designed for FDA performance standard |
 |
| Model 007 |
| |
| |
The
CIRS CT Dose Phantom is manufactured to comply with the Food and
Drug Administration's performance standard for diagnostic x-ray
systems, which includes Computed Tomography Systems (21CFR 1023.33). |
|
| |
| Each phantom consists of two 14cm thick solid PMMA disks measuring
16 cm (head) and 32 cm (body) in diameter. |
| |
| The disks have five through-holes with an inside diameter of 1.31cm
to accommodate standard CT dose probes and five acrylic rods to
plug the holes not in use. One hole is at center and four are around
the perimeter, 90° apart and 1cm from hole center to the outside
edge of the phantom. |
| |
The head and
body phantoms along with the ten acrylic rod plugs are packaged
in an extremely rugged foam lined carrying case. |
| |
| Features: |
- Useable
on all CT Scanners.
- Head and
abdominal configurations included.
- Made from
acrylic with a density of 1.19 grams/cc.
- Includes
10 PMMA plugs.
- 1.31 cm
inside hole diameter sized for standard CT Dose probes.
- Rugged
foam lined carrying case included.
|
| |
 |
|
 |
|
|
|
|
|
|